Paramètres related to :

PMC Signals – DI/DO.

 

Symbol

Param

Bit

Description

 

TMF

0009

4

Delay time between M, S, T Codes and MF, TF, SF Strobe.

 

TFIN

0009

0

Time of reception width of  FIN Signal.

 

MCINP

0011

7

1= Program input start with signal ‘’MINP’’

 

RILK

0015

2

1= Intlk. At high speed;   0= Intlk. At normal speed.

 

C4NG

0019

1

1= 4th axis neglect signal is valid.

 

BCD3

0020

4

Output B code is 1= 3 Digits;   0= 6 Digits.

 

IGNPMC

0024

0

1= Control by PMC is made ineffective.

 

EXTS

0028

4

Search by external 1= Prgrm (1-9999);   0= 1-15.

 

HSIF

0045

7

M/S/T/B Code process :   1= High speed;   0= Normal Interface.

 

RDIK

0049

1

0= The high speed interlock signal always valid.

 

DILK

0049

0

1= Each axis interlock signal valid only in manual operation.

 

PRSTCT