Paramètres related to :
Symbol |
Param |
Bit |
Description |
|||
TMF |
0009 |
4 |
Delay time between M, S, T Codes and MF, TF, SF Strobe. |
|
||
TFIN |
0009 |
0 |
Time of reception width of FIN Signal. |
|
||
MCINP |
0011 |
7 |
1= Program input start with signal ‘’MINP’’ |
|
||
RILK |
0015 |
2 |
1= Intlk. At high speed; 0= Intlk. At normal speed. |
|
||
C4NG |
0019 |
1 |
1= 4th axis neglect signal is valid. |
|
||
BCD3 |
0020 |
4 |
Output B code is 1= 3 Digits; 0= 6 Digits. |
|
||
IGNPMC |
0024 |
0 |
1= Control by PMC is made ineffective. |
|
||
EXTS |
0028 |
4 |
Search by external 1= Prgrm (1-9999); 0= 1-15. |
|
||
HSIF |
0045 |
7 |
M/S/T/B Code process : 1= High speed; 0= Normal Interface. |
|
||
RDIK |
0049 |
1 |
0= The high speed interlock signal always valid. |
|
||
DILK |
0049 |
0 |
1= Each axis interlock signal valid only in manual operation. |
|
||
PRSTCT |
0252 |
|