Paramètres related to :
Symbol |
Param |
Bit |
Description |
||
THJD |
0002 |
6 |
1= Handle Feed Possible with MPG in teach in Mode. |
||
HSLE |
0003 |
7 |
1= When 3 Mpg’s; Axis select sign. Is valid. |
||
NZMP4 |
0018 |
3 |
Hndl Feed *100 for 4th axis : 1= Ineffectiv; 0= Effective. |
||
NZMP2 |
0018 |
2 |
Hndl Feed *100 for Z axis : 1= Ineffectiv; 0= Effective. |
||
NYMP2 |
0018 |
1 |
Hndl Feed *100 for Y axis : 1= Ineffectiv; 0= Effective. |
||
NXMP2 |
0018 |
0 |
Hndl Feed *100 for X axis : 1= Ineffectiv; 0= Effective. |
||
MHPGB |
0019 |
0 |
Multi-Handle function is specification : 1= B; 0= A. |
||
H4/ZNO |
0117 |
|
MPG NBR. Of Z/4th in Multi-Handle B Specif : 1 to 3. |
||
NUMHG |
0118 |
|
Number of Man. Puls Generator to be used in Multi-Handle. |
||
MULHPG |
0121 |
|
Multiplier N of the Manual Handle Feed. Set. 1-127. |
||
JHD |
0013 |
0 |
1= MPG is valid in Jog Mode; 0= MPG is not valid. |
||